APC Smart-UPS RT 10kVA 230V SRTG10KXLI
$5,245.00
- Part Number: SRTG10KXLI
- Lead time: Usually in Stock
- Run time for load: 10000 W
- Min-max: 1000-10000 W; 3min 32s
- Max. Capacity Used: 100 %
- Main Input Voltage: 230 V
- Other Input Voltage: 220 V, 240 V
- Main Output Voltage: 230 V
- Warranty: 3 years repair or replace (excluding battery) and 2 years for battery
Contact for Price & Stock
Delivery 25 Provinces
Official Warranty
100% Genuine Product
Tech Support
Specifications
- Part Number: SRTG10KXLI
- Overview
- Lead time: Usually in Stock
- Main
- Run time for load: 10000 W
- Min-max: 1000-10000 W; 3min 32s
- Max. Capacity Used: 100 %
- Main Input Voltage: 230 V
- Other Input Voltage: 220 V, 240 V
- Main Output Voltage: 230 V
- Other Output Voltage: 220 V, 240 V
- Rated power in W: 10000 W
- Rated power in VA: 10000 VA
- output connection type
- 2 IEC 60320 C13
- 1 IEC 60320 C19
- Output connector type: Hard wire 3-wire (H N + E) 1
- Battery type: Lead-acid battery
- Provided equipment
- Smart UPS signalling RS-232 cable
- User manual
- General
- Number of power module free slots: 0
- Number of power module filled slots: 0
- Redundant: No
- Physical
- Height: 21.7 cm
- Width: 44 cm
- Depth: 68 cm
- Net weight: 101.44 kg
- Mounting preference: No preference
- Mounting mode: Rack-mounted with kit
- Two post mountable: 0
- USB compatible: No
- Input
- Network frequency: 40...70 Hz auto-sensing
- Number of input connectors: 1 hard wire 3-wire (1P + N + E)
- Input voltage limits: 160...285 V
- Maximum input current: 30 A
- Max short time withstand current: 40 kA
- Output
- Maximum configurable power in W: 10000 W
- Harmonic distortion: Less than 2 %
- Output frequency: 50/60 Hz +/- 3 Hz sync to mains
- Crest factor: 3 : 1
- UPS type: Double conversion online
- Wave type: Sine wave
- Bypass type: Internal bypass (automatic and manual)
- Full load runtime: 00:03:30 10000 W
- Half load runtime: 00:11:00 5000 W
- Maximum configurable power in VA: 10000 VA
- Conformance
- Standards
- EN/IEC 62040-1:2019/A11:2021
- EN/IEC 62040-2:2006/AC:2006
- EN/IEC 62040-2:2018
- Environmental
- Ambient air temperature for operation: 0…40 °C
- Relative humidity: 0…95 % non-condensing
- Operating altitude: 0...6600 ft
- Ambient air temperature for storage: -15…45 °C
- Storage Relative Humidity: 0…95 % non-condensing
- Storage altitude: 0.00…15240.00 m
- Acoustic level: 55 dB
- heat dissipation: 2217.98 Btu/h
- IP degree of protection: IP20
- Batteries & Runtime
- Run Time: View Runtime Graph
- Efficiency: View Efficiency Graph
- Number of battery filled slots: 0
- Number of battery free slots: 0
- Battery recharge time: 4 h
- Additional information: Configurable for 220 : 230 or 240 nominal output voltage
- Battery voltage: +/- 96 V
- Battery charger power: 431 W rated
- Battery power in VAH: 1772 VAh runtime
- Battery option
- SRTG192XLBP4 1 3564 VAh
- SRTG192XLBP4 2 5415 VAh
- SRTG192XLBP4 3 7378 VAh
- SRTG192XLBP4 4 9216 VAh
- Extended runtime: 1
- Communications & Management
- Preinstalled device: Network management card 3 with environmental monitoring
- Alarm: Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
- Emergency power off: Yes
- Surge Protection and Filtering
- Surge energy rate: 600 J
- Packing Units
- Unit Type of Package 1: PCE
- Number of Units in Package 1: 1
- Package 1 Height: 41.4 cm
- Package 1 Width: 79 cm
- Package 1 Length: 59 cm
- Package 1 Weight: 103.46 kg